Flex-Lok Ball Joint Pipe

The following tables show suggested water pressure ratings with thickness designations and weights in accordance with applicable requirements of ANSI/AWWA C150/A21.50 and ANSI/AWWA C151/A21.51. It is intended that the ultimate determination of suitable thicknesses should be made by the design engineer with consideration of both installation methods and ultimate service conditions of the line.

4"–24"

Size
(in.)
Working
Pressure1
(psi)
T
Wall
Thickness2
(in.)
Weight in Pounds Underwater Weight Per
Length Incl. Joint Materials3
Per Pipe
Length
Per Length
Incl. Joint
Materials
Per Foot
Incl. Joint
Materials
Full of Air
(lbs.)
Full of Water
(lbs.)
4 250 0.41 345 375 18.3 206 325
6 250 0.43 605 645 31.5 302 555
8 250 0.45 840 895 43.7 306 770
10 250 0.47 1100 1170 57.1 284 1005
12 250 0.49 1390 1480 72.2 231 1275
14 250 0.51 1760 1880 91.7 193 1615
16 250 0.52 2045 2200 107.3 15 1880
18 250 0.534 2425 2610 127.3 -1294 2245
20 250 0.544 2810 3040 148.3 -3274 2610
24 250 0.564 3605 3910 190.7 -8894 3360
Size
(in.)
OD
(in.)
N
(in.)
Joint Materials
Weight in Pounds
Lubricant
Pounds
Per Joint
Gland Gasket Locking
Wedge
Complete
Set
4 4.80 11.79 27 1 1 29 0.09
6 6.90 13.91 37 1 1 39 0.12
8 9.05 16.38 50 1 2 53 0.16
10 11.10 18.84 67 1 3 71 0.27
12 13.20 21.56 89 1 3 93 0.40
14 15.30 24.43 115 2 3 120 0.50
16 17.40 26.78 147 3 4 154 0.60
18 19.50 29.70 181 3 4 188 0.75
20 21.60 32.59 221 4 4 229 0.90
24 25.80 37.29 297 5 4 306 1.10

30"–60"

Size (in.)5 Working Pressure1
(psi)
T Wall Thickness6 (in.) Weight in Pounds Underwater Weight Per
Length Incl. Joint Materials3
Per Pipe Length Per Length Incl. Joint Materials Per Foot Incl. Joint Materials Full of Air4
(lbs.)
Full of Water
(lbs.]
30 250 0.63 5735 5759 266.8 -2017 4944
36 250 0.73 8455 8499 384.9 -2914 7296
42 250 0.83 12225 12287 546.1 -3506 10548
48 250 0.93 16050 16138 717.2 -4486 13855
54 250 1.05 22440 22587 982 -4688 19388
60 250 0.87 26650 26875 1156 -5920 23410
Size
(in.)
OD
(in.)
N
(in.)
Joint Materials Weight in Pounds Lubricant
Pounds
Per Joint
Locking
Ring
Gasket Locking
Clip
Complete
Set
30 32 40.57 17 6 1 24 1.6
36 38.3 48.43 35 8 1 44 2.2
42 44.5 56.71 53 8 1 62 2.7
48 50.8 63.67 77 10 1 88 3.5
54 57.56 73.37 121 22 2 145 4.7
60 61.61 80.13 198 27 3 228 10

1 The working pressure is AMERICAN’s suggested standard water working pressure. Contact AMERICAN if higher working pressure is required.

2 Thicknesses correspond to Special Class 56. Check with AMERICAN if pipe with other wall thickness is required.

3 Does not include lining weight. Underwater pipe weights are for fresh water. Sea water is approximately 3% heavier than fresh water, and these weights should be adjusted accordingly for sea water installation.

4 When full of air, pipe of this thickness will float unless weight is added. See Weights for Standard Cement Lining. Gross weight, including pipe, gland and lining, is painted on each length of Flex-Lok pipe to aid in field calculations of actual buoyancy.

5 Check with AMERICAN on requirements for 64" Flex-Lok.

6 Thicknesses correspond to special class 56 for 30"-54" sizes and Pressure Class 350 for the 60" size. Check with AMERICAN if pipe with other wall thickness is required.

Request More Information

Add specific model info if applicable

Tell us more

Print Page