Laying Lengths

Size
(in.)
Minimum Dimensions in inches
Flg-T/C-Flg Flg-T/C-PE PE-T/C-PE MJ-T/C-MJ (Fab1) MJ-T/C-PE MJ-T/C-Flg Fst-T/C-PE Fst-T/C-Flg
O.A./L.L. O.A./L.L. O.A./L.L. O.A. L.L. O.A. L.L. O.A. L.L. O.A. L.L.1 O.A. L.L.1
4 8 8 8 10 4 5/8 8 5 1/2 8 5 1/2 8 4 11/16 8 4 5/8
6 8 8 8 10 4 5/8 8 5 1/2 8 5 1/2 8 4 5/8 8 4 5/8
8 8 8 8 10 4 5/8 8 5 1/2 8 5 1/2 4 1/4 8 4 1/4 4 1/4
10 8 8 8 10 4 5/8 8 5 1/2 10 7 1/2 8 4 1/4 7 1/4 3 1/2
12 8 8 8 10 4 5/8 8 5 1/2 10 7 1/2 8 4 1/4 7 1/4 3 1/2
14 8 1/2 8 8 12 4 1/2 8 4 1/2 11 7 1/2 8 2 3/4 9 3/4 4 1/2
16 8 1/2 8 8 12 4 1/2 8 4 1/2 11 1/2 8 8 2 3/4 9 3/4 4 1/2
18 8 1/2 8 8 12 4 1/2 8 4 1/2 12 8 1/2 8 1 1/2 10 4 1/2
20 8 1/2 8 8 12 4 1/2 8 4 1/2 12 8 1/2 8 1 1/2 10 4 1/2
24 9 1/2 8 8 12 4 1/2 8 4 1/2 12 8 1/2 8 1 1/2 10 4 1/2
30 12 10 1/2 8 - - - - - - 8 1 1/2 12 5 1/2
36 14 11 1/2 8 - - - - - - 8 1 1/2 12 5 1/2
42 16 12 8 - - - - - - 8 1/2 1 14 6 1/2
48 16 12 8 - - - - - - 9 1 15 7
54 18 16 8 - - - - - - 9 1/2 1 16 7 1/2
60 18 16 8 - - - - - - 9 3/4 1 16 7 1/4
64 18 16 8 - - - - - - 10 1 16 7
1.) Thrust collars may not be located in exact center of all minimum length pieces shown above.
2.) Laying lengths are rounded to the nearest 1/4".

Flange–Thrust Collar–Flange and Flange–Thrust Collar–PE pipe may be furnished up to 20’-0" length (with the exception of 4" whose maximum length is 17’-6"). Contact AMERICAN if longer lengths required.